Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Round Control Dampers. CFD7T - 2"x4" Truss Assemblies (Ref. Static pressure and CFM are corrected to . Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. CD60 | Galv. G. com W: Ruskin® manufactures an extensive line of UL-rated and listed dampers to protect your life and property. Ruskin ® Terms and Conditions for more information. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. The EFL is standard on all fire/ smoke dampers ordered with electric actuators. Inspiring the industry with thought provoking, revolutionary ideas, Ruskin airfoil blade dampers comprise the only damper design incorporating a single piece roll-formed frame and blade. To meet the diversity of fire and smoke protection requirements,. The CD60CE is designed for coastal regions and other corrosive environments such as salt-water regions. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Leakage information based on pressure differential of 1" w. The EFL is STANDARD on all fire/smoke dampers ordered with electric actuators. g. Location of Damper in Ductwork Smoke Dampers must be placed in the ductwork so the closed blades are within 24” (610) of the smoke barrier and before any duct inlets or outlets (access doors not included). The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Single Blades. ©Ruskin 2000 3900 Dr. To determine the pressure drop: 1. 21. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. The CD60GS is designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment orsurrounding space. The standard finishes described herein represent those finishes usually selected, specified, or required for most. Every damper is built with performance in mind and tested per AMCA standards. Mounting Angle Fasteners Sleeve: #10 bo lts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. 3 (damper installed with duct upstream and downstream). See “Combination Fire Smoke Damper Multiple Section Detail” specPerfect for a Wide Variety of Applications. Ruskin Literature. 1. Mounting Angle Fastener Spacingon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Dampers shall be in all respects equivalent to Ruskin model CBD6. Consult Ruskin or your Ruskin repre-sentative when a damper is to be applied in conditions exceeding recommended maximums. TION 1. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. 025” thick formed aluminum with concealed blade linkage, synthetic bearings. Greaves Rd. effort to avoid misapplication. FSD35. In addition, the DC models have. RUSKIN provides most finishes available to architects and engineers. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. dampers are for use in dynamic (fans on) or static (fans off) sys-tems. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Phone. (Consult Ruskin for detailed CSI MasterFormat Specification. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Louver blades are . The CD80AF2 Industrial Control damper has an 8" frame. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. 5hr Dynamic Fire Dampers » 3hr Dynamic Fire Dampers » 1. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Ruskin's Insulating Control Dampers are perfect for performing this task. 7447 Toll Free: 800. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural. Note: Multiple section dampers are not intended to be structural supports. Standard damper assemblies are furnished ¼” smaller. Maximum. g. Ruskin Brands and Locations. It features: Extruded aluminum construction. ©Ruskin 2000 3900 Dr. CDR25 and CDO25 dampers are round and oval volume control dampers. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Determine area factor for damper by entering the Area Factor Table through duct width and height. • Ruskin frame-mounted actuator bracket to simplify field installation of most actuators (specify actuator and action, i. (1 kPa). used in conjunction with Ruskin fire/smoke dampers. g. Certain actuators in Table 1 are UL Recognized Components under. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). 01" w. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. Dampers shall be in all respects equivalent to Ruskin Model CD40. yeoching. As a Corridor Damper it is designed to be used in openings in the ceilings ofRuskin anuary 2021 Page 2 1. 2. 75" w. 5Hr » Combination Fire/Smoke Dampers 3Hr » Smoke Dampers » Corridor Dampers » 1. FILES (0) Share this page: Catalog. Do not weld or fasten angles together at cor-ners of dampers. (Dampers with V-Groove blades are structurally designed for velocities to 2000 FPM and above. g. The maximum opening. • Operation Test The damper/actuator assembly is exposed to heated (250ºF or 350ºF) airflow (minimum 2,400 fpm and 4. Greaves Rd. ©Ruskin October 2007 ® Spec FSD60-C-1007/Replaces FSD60/36-C-1206 APPLICATION The FSD60-C is two dampers in one. 6 Pneumatic Damper Actuator is recommended for control of outdoor, return air, exhaust, face and bypass, and fan discharge dampers. The damper is rated for maximum velocity of 2,000 fpm (10. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowDamper is designed to operate with blades running horizontally and m ust be installed with center line of damper blades within the wall or floor when they are in the closed position. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. The FSDR60 is the ideal choice when round duct is used on a project. It is recommended for heavy duty applications using multi-section dampers where either unison or sequence operation is required. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. FILES (0) Share this page: Trusted for decades, Ruskin V-Groove blade dampers were designed to extend a lower cost solution for standard duty (medium or low pressure) applications. g. When used in fan discharge applications, damper should be the damper frame. (Consult for electronic version of this “Quick” spec as well as for complete 3-part CSI MasterFormat Specifications)Ruskin model TED50DC offers high performance and reliability for HVAC systems serving data center facilities. cheng@jci. NOTES: 1. Louver blades are . 3 sq. Ruskin model ZBBD25 barometric bypass dampers are used to automatically bypass excess air when the duct static pressure increases due to the closing of zone dampers. Our dampers are ideal for outdoor air applications that require low leakage or heavy duty industrial needs to prevent hot or cold outside air penetrating your building. 3900 Dr. Refer to the UL approved installation instructions for specific requirements. Ruskin Green Products. dampers. g. Louver and Architectural Solutions. The airfoil blades are designed for HVAC systems with velocity and pressures up to 4,000 fpm and 8" w. @ 1" w. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. @ 4" w. Curtain Type Static Fire Dampers 1 1/2 Hour UL555 Rated For Use In Static System Ruskin Model IBD20, 40, and 60 are 1 1/2 hour UL classified static (fans off) curtain style fire dampers for use in HVAC systems that shut down during a fire event. lbs. g. The CFD2 is a UL555C Classified Ceiling Fire Damper. Aluminum construction. g. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. Mounting Angle FastenersCurtain Type Static Fire Dampers 3 Hour Ul555 Rated For Use In Static Systems Ruskin Model IBD23 is a 3 hour UL classified static (fans off) curtain style fire damper for use in HVAC systems that shut down during a fire event. The product is not cancelable or returnable unless found defective. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowIBD2G, IBD2SSG (Static) and DIBD2G, DIBD2SSG (Dynamic) curtain type fire dampers for grille installation may be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Rectangular Silencers. lbs. Dampers Corridor Dampers Fire Dampers Smoke Dampers Ruskin® 3900 Dr. AXLE All axles to extend 6" (152) beyond damper frame. The results show that Ruskin’s CBS8BL dramatically reduces the blast impulse thus protec Ruskin blast damper charts below highlight results of independent third party lab testing of model CBS8BL to peak reflective pre B Impl ( ows ra m Ope nDu ct) Blast Impulse (Downstream Damper)of damper with minimum of 20 in. A 1" (25) diameter jackshaft is normally used for. They are easy to install, easy to use, and are customizable to the needs of any building automation system. 6 psi to 44. Backdraft blades are . Zone Control Systems. , Ltd. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. 00. • For proper operation, damper must be installed square and free from racking. 350° Horizontal FSD36LP 36"x 14" 4"w. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. Rev. pressure drop through Ruskin CD/OD102 Dampers. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. Stainless Steel Construction See model (D)IBD2SS. See “Combination Fire Smoke Damper Multiple Section Detail” specRuskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. 2 m/s) and 4” w. Damper size shall not exceed 90" x 48" (2286 x 1219) or 48" x 90" (1219 x 2286). Ruskin CD30AF1/CD30AF2 con-trol dampers. Ruskin's complete line of zone control products was developed to meet an increasing demand for zone specific products combined with individual controls. The CBD2 is an extremely sensitive gravity operated backdraft damper. GENERAL INSTALLATION NOTES 1. UL approval for dual directional air flow. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. back pressure depending on damper size. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. 3. g. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. If the actuator must be mounted on top or bottom, select the FSD60V. Noise Control. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Readily connects to round spiral or flexible ductwork. w. The Damper Test Switch (DTS) is an optional “momentary” push button test switch available on Ruskin fire/smoke dampers. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. per sq. These same finishes provide extended weathering resistance similar to adjacent building surfaces. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. The majority of designs are rated at 2 or 3 hours. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Enter your email and join our mailing listDesigned for isolation and containment of the airstream, Ruskin bubble tight industrial dampers for round or rectangular air paths will meet or exceed bubble tight leakage requirements in conformance with AMCA Standard 500D and are available with factory-supplied and mounted actuation. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/Steel Stud Wall: #10 screws. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. While is it true that triple V blade dampers and modified single skin type have been qual-ified to 3000 - 4000 fpm or more at 4" w. static pressure. lbs. Unlike other ceiling. Non-stick, noncorrosive bearings that assure. Dampers shall be Ruskin Swartwout Series Mod el 912 FRP control dampers or equal. Greaves Rd. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Spec vFBD35-818/Replaces VFBD35-708 ©Ruskin August 2018 • 3900 Dr. Each fire damper shall be labeled for use in dynamic systems. 5 in. Damper shall be Ruskin model BTR82. g. Hours: 9am - 5pm CDT M-F. Backdraft blades are . M. Fusible Link which is included at no extra charge. Ruskin August 2020 Page5 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. a. It features: UL555S Class I leakage class. Dampers shall be Ruskin model FSDR25. 025" thick formed aluminum with concealed blade linkage, synthetic bearings and non. (2 kPa). Maximum velocity for V-Groove blade 2000 FPM and Airfoil blades 3000 FPM. The calibrated locking hand quadrant is coordinated with specific aperture. Static only damper labels are not permissible. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 ® Nominal Diameter, Inches Total CFM. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. It features: Extremely low leakage. Dynamic fire dampers shall be Ruskin multiple model DFD60. 2 m/s) and 4” w. Built from strong materials and designed on state-of-the-art. We are the leading manufacturer of air. max Extremely tight shut-off. , N. Zone Control Systems. It is rated as a 1-1/2 hour fire damper and a Leakage Class II Smoke damper. g. UL qualifies the damper and its actuator for performance after 30 minute exposure to elevated temperatures. Ruskin Green Products. The unit has encapsulated iris segmented blades and integral air pressure taps for great flow control and validation. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Supported by US Headquarters, Ruskin is the world largest and innovative air control solutions manufacturer, we combine financial stability with pioneering. The. 3. It is made of durable PVC materials and has a simple design that allows easy installation and operation. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for steel joist assemblies (L524). TION 1. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. 3. MODEL 912 SUGGESTED SPECIFICATION Suggested specification for Model 912 Ruskin Swartwout Fiberglass Series round dampers (revision 6394). Name. 5" w. Stainless Steel V-Groove Blades. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERS Catalog. 4 inches w. Pressure Relief Doors. It features: A static pressure control option, which enables field adjustment to maintain static pressures ranging up to . Electric and pneumatic actuators are available with numerous accessories and mounting. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. The uick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Ruskin FAST and PFMA are 20 gauge steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. Pressure drop and free area may vary. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Blades have an integral structural reinforcing tube running full length of each blade. A change anywhere is a change everywhere, instantly!2. would require CD50 damper with maximum section width of 36" (914). The CD35 commercial control damper offers sturdy, steel construction with interlocking frame design. 25" w. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. 2 m/s) and 4” w. 3. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. All installations shall be in accordance with manufacturer's published installation instructions. Welcome to Ruskin Rooftop Systems. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Get free shipping on orders over $999!%PDF-1. Greaves Rd. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. Air Measuring Station with Integral Damper: 15" 300-5000: Transducer (LCD Display Optional) Optional: 3%: W 6" H 6" W 60" H 72" Velocity Pressure:. The CFD7T-SR is a UL Classified Ceiling Fire Damper listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548, P572, and H502. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. pressure) for 15 minutes. 3. to. 2. 8) galvanized steel struc-Products. The Diffuser Radiation Shield, which allows any manufacturer's lay-in style steel ceiling diffuser (subject to gage and dimension limitations) to be installed in UL Classified F/C or R/C assembly with Fire. a. Leading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec-ommended maximums. Learn about their history, products,. Dampers above 18" (457) – 10 gage steel (3. The damper ships with a factory mounted and commissioned 24 VAC, spring return actuator set to power closed and spring or "fail" open. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood Factory or field supplied plenums Assembly designed to accept grilles with up to 2 1/2" grille depth with OBD Through ceiling. Ruskin Model ZCDR25 can be installed into existing round ductwork. 3 m/s) and 8” w. L501). and greater Carbon steel construction Butterfly bladeThe CFD7T-ST-BT is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. Unlike conventional mounting angles that cannot be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: One piece angles (fastened together in the corners). Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. six plant locations, Ruskin is meeting the needs of contractors and engineers around the globe. See “Smoke Damper Multiple Section Detail” spec sheet for details. Maximum 8" static pressure. angles together at corners of dampers. Easy installation. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Furnish and install, at locations shown on plans or in accordance with schedules, counterbalance backdraft dampers that meet the following minimum construction standards: frame shall be (specify). Ruskin CFD(R)2 and CFD(R)3 are UL Classified to provide protection to HVACRectangular Steel V-Groove. ft. NOTE: Dampers may tolerate higher pressures and velocities than those listed here. The CD60SS in 304 stainless steel construction offers corrosion resistance and Class IA leakage performance of 3cfm/ft @ 1" w. g. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Learn about their history, products, news and experts on their website. Masonry/Wall or Floor: #10 self-tapping concrete screws. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. 1. Damper bearings shall be of UHMW and mechanically fastened by stainless steel set collars located out of the airstream. The CFD7 is UL555C Classified Ceiling Fire Damper for wood construction. Spec CBD4-507/Replaces CBD4-92000 ©Ruskin 2007 *Unit furnished approx 1/4" (6). DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. Fiberglass Series round backdraft dampers. Actuators enable a damper to operate with controlled positioning throughout the stroke of the damper. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. Greaves Rd. ft. Rusin anuary 2021 Replaces Spec AIRFLOW-IQ-01 Pae 4 High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. INSTALLATION For proper operation, damper must be installed square and free from racking. When installed as shown, they provide appropriate protection for air inlet or outlet penetrations in the ceiling membrane of floor/ceiling and roof/ceiling assemblieslabel and is classified as a static damper for use in HVAC systems that shut down during a fire. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Frame shall be 16 ga. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. FSD36 126"x 96"or 72"x 122" 4"w. 2. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). The TDP05K is capable of measuring a velocity range from Oto 5,000 FPM and displaying the flow and temperature. These fire dampers are used for the protection of openings in walls, partitions, or masonry floorsDamper Dia. They are designed to be installed inside duct work rather than flange mounted. lbs. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. It is Leakage Class I classified and features: UL555S Class I. a. Dampers shall be in all respects equivalent to Ruskin model IL35. b. Ceiling Fire Dampers UL Classified Radiation Dampers Underwriters Laboratories has classified hundreds of specific Floor/Ceiling (F/Cs) and Roof/ Ceiling (R/Cs) and established Fire Resistance Ratings for each design ranging from 1/2 to 5 hours. The TS150 allows the dampers to be reopened after the initial closure for dynamic smoke control. Grandview, MO 64030 View our location on Google Maps Phone: 816. Dynamic fire dampers shall be Ruskin model DFD60-3. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. AMCA licensed as a class 1A damper. Ruskin® A 0 Page 1 CD60CE Critical Environment High performance 316 stainless steel airfoil blade damper AMCA Class IA Leakage Rated The High-Performing Ruskin Model CD60CE is designed to control and regulate air movement in medium to high velocity and pressure HVAC Systems. Performance curves based on AMCA Standard 500 using test setup appratus figure 5. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Warranty claims under this Limited Warranty should be referred to: Ruskin 3900 Dr. Figure 5. It features: Galvanized steel construction. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power The EFL or PFL heat-actuated release devices permit controlled. Ruskin model TED50XT offers HVAC design engineers an ultra-low leak thermally efficient damper which provides: • Energy savings for building owners • Effective resistance to condensation in climate prone areas. pivot pins. . • Airfoil blade design for low pressure drop and reduced noise generation. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Noise Control. > Case Studies. for dampers up to 17. Life Safety » Combination Fire/Smoke Dampers 1. LEADS; TDP05K Placement Tool; Windload Calculator; Resources. upstream of the damper. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. To provide even greater control of dampers in HVAC systems, Ruskin also. The damper shall be rated for dynamic closure at 2000 fpm (10. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. Industrial Fiberglass Louvers.